TradeinSafe
Cart
Science Gears Pty Ltd

Science Gears Pty Ltd

Potentiostats / Galvanostats · 🇦🇺 AU

View supplier storefront →

Verified
5+Yrs
0Orders
NewRating
Image 1
1 / 2
Click to zoom

Science Gears Pty Ltd · Potentiostats / Galvanostats

Pitting corrosion potential measurement potentiostat CS300M

0.0(0 reviews)·✓ 0+ verified orders

WHOLESALE UNIT PRICE

—

Bulk pricing available

Quantity

1
— total
🔒Escrow Protected
🏭Factory Verified
🚢Ships Globally
🇦🇺
Ships from

Queensland, Australia

⏱️
Lead time

3–7 days (AUS) · 7–21 days (INT)

💳
Payment

T/T · PayPal · Escrow · L/C

📜
Certifications

—

🌐
Export to

200+ countries · All major markets

CS300M Potentiostat/Galvanostat contains a fast digital function generator, high-speed data acquisition circuitry, a potentiostat and a galvanostat. With high performance in stability and accuracy with advanced hardware and well-functioned software, it is an entery and cost-effective model. With methods such as Potentiodynamic (Tafel plot), it’s widely used to measure pitting corrosion potential. International standards of pitting corrosion potential measurement: China: GB 4334.9-84 USA: ASTM G61-1986(2014) Japan: JIS G0577-1981 Other standards GB/T 17899-1999 GB/T 18590-2001 GB/T 32550-2016 Industry standards YY/T 1074-2002 YY/T0149-2006 YY/T 0695-2008 Experiment setup Software parameters’ setting Typical Pitting potential

Technical specifications

Model / SKUSCIGEAR00140
CommunicationRS485
Current range20A/40A/100A fixed range
Potential range±10V(CS2020B) / ±5V(CS2040B) / ±5V(CS2100B)
Compliance voltage±13V (when output±20A limit current, maximum output ±10V@20A)
Interface: USB 2.0Weight / Measurements: 6.5kg, 36.5 x 30.5 x16 cm
EIS Frequency range≤50KHz
Maximum current output: 2ACV and LSV scan rate: 0.001mV~10,000V/s
Potential control range: ±10VCurrent control range: ±2A
Current range: 2nA~2A, 10 rangesCompliance voltage: ±21V
Low-pass filters: covering 8-decadeOperating System: Windows 10/11
DA Resolution:16bit, setup time:1μsMinimum potential increment in CV: 0.075mV
Support 2-, 3- or 4-electrode systemPotential and current range: Automatic
CA and CC pulse width: 0.0001~65,000sCurrent increment during scan: 1mA@1A/ms
DPV and NPV pulse width: 0.0001~1000sAD data acquisition:16bit@1 MHz,20bit@1 kHz
Rise time: <1μS (<10mA), <10μS (<2A)Reference electrode input impedance:1012Ω||20pF
Potential increment during scan:0.076mV@1V/msSWV frequency: 0.001~100 kHz
Potential control accuracy:0.1%×full range±1mVCurrent control accuracy: 0.1%×full range
Potential resolution: 10μV (>100Hz),3μV (<10Hz)Current sensitivity:1pA