Potentiostats / Galvanostats · 🇦🇺 AU
View supplier storefront →

Science Gears Pty Ltd · Potentiostats / Galvanostats
WHOLESALE UNIT PRICE
—
Quantity
Queensland, Australia
3–7 days (AUS) · 7–21 days (INT)
T/T · PayPal · Escrow · L/C
—
200+ countries · All major markets
Portable all-in-one electrochemical workstation for lab and field work The MicruX ECStat (ECSTAT2020) is a compact, USB-powered electrochemical station that integrates a bipotentiostat/galvanostat , zero-resistance ammetry (ZRA) capability, and a built-in frequency response analyser for electrochemical impedance spectroscopy (EIS) . It is designed for researchers who need reliable electrochemistry in a lightweight format for bench, teaching, or mobile testing. How it works (principle of operation) At its core, the ECStat controls the electrode potential using feedback electronics to maintain a defined potential at the working electrode(s) relative to a reference electrode , while measuring the resulting current through a counter electrode . In bipotentiostat mode, two working electrodes can be driven and monitored for advanced experiments (for example, generator–collector style workflows and dual-channel sensing studies). The integrated EIS module applies a small AC perturbation and measures the frequency-dependent response to resolve charge-transfer, diffusion, and interfacial processes. Key features and specifications DC potential range: ±10 V Maximum current: ±30 mA; measurement ranges down to the pA level EIS/FRA frequency range: 10 μHz to 1 MHz Operating modes: bipotentiostat, potentiostat, galvanostat, ZRA, PEIS Software: MicruX EC Manager for method setup, real-time plotting, export and analysis Form factor: compact instrument supplied with accessories in a carry case Compatibility and typical applications Compatible with screen-printed electrodes (SPEs) , thin-film electrodes, and common electrochemical platforms, making it well suited for: Biosensor development and electrochemical sensing Corrosion and inhibitor screening (including ZRA-style measurements where relevant) Electrocatalysis and reaction mechanism studies (CV, LSV, DPV, SWV, etc.) Teaching labs and portable demonstrations of EIS and voltammetry Why source it through ScienceGears (AU & NZ) ScienceGears supports researchers across Australia and New Zealand with application guidance, compatible electrochemical cells/electrodes, and pathway upgrades into broader platforms such as research potentiostats, battery cyclers, or spectroelectrochemistry (e.g., Raman-SEC cells) when experiments scale beyond portable measurements.
| Weight | 0.5 Kg |
| Dimensions | 160 x 100 x 45 mm (L x W x H) |
| Model / SKU | SCIGEAR00199 |
| Current ranges | 100 pA to 10 mA (max. current: ± 30 mA) |
| Frequency range | 10 μHzto 1 MHz |
| Maximum current | ±30 mA |
| Operating modes | Bipotentiostat, Potentiostat, ZRA, Galvanostat, PEIS analyzer |
| potential range | ±10 V |
| Current accuracy | ≤0.1 % (at Full Scale Range) |
| Compliance voltage | ±10 V |
| 0.006 % of current range | (5 fAon 100 pArange) |
| Applied potential accuracy | ≤0.1% ±1 mV offset |
| Measured current resolution | 0.006 % of current range (5 fAon 100 pArange) |
| Applied DC-potential resolution | 75 μV |