Potentiostats / Galvanostats Β· π¦πΊ AU
View supplier storefront β

Science Gears Pty Ltd Β· Potentiostats / Galvanostats
WHOLESALE UNIT PRICE
β
Quantity
Queensland, Australia
3β7 days (AUS) Β· 7β21 days (INT)
T/T Β· PayPal Β· Escrow Β· L/C
β
200+ countries Β· All major markets
& Principle This high-current booster series extends the output capability of a host potentiostat/galvanostat to support demanding electrochemical loads. When paired with a compatible single-, bi- or multi-channel workstation, the booster routes the control signal from the potentiostat and delivers a proportionally higher current to the cell while the base instrument maintains potential control and data acquisition. Available variants raise the current limit to ±20 A, ±50 A, or ±100 A for one channel at a time, enabling accurate potential-controlled experiments on large-area or low-impedance cells. Current Booster Model Comparison Model Maximum Current Max. Applied Potential Potential/Current Control Accuracy Compliance Voltage EIS Frequency Range Communication CS1020B ±20 A ±10 V 0.1% ±13 V 10 µHz–50 kHz Connect with potentiostat CS1050B ±50 A ±10 V 0.1% ±10 V 10 µHz–50 kHz Connect with potentiostat CS10100B ±100 A ±10 V 0.1% ±10 V 10 µHz–50 kHz Connect with potentiostat CS5010B ±10 A ±50 V 0.1% ±50 V 10 µHz–50 kHz Connect with potentiostat Key Features & Specifications Models: CS1020B / CS1050B / CS10100B (±20 A / ±50 A / ±100 A) Integration: Connects to Corrtest single-channel (e.g., CS350M/CS310M/CS300M) and to one channel of bi- or multichannel systems (e.g., CS2350M/CS2150M/CS310X). One booster drives one channel of a bi-/multichannel frame. Base instrument ranges (for context): typical standalone limits are up to ±2 A/±10 V for single-channel units and ±1 A/±10 V per channel for bi/multichannel systems; the booster elevates current capacity while potential control remains with the host. Compliance & voltage: governed by the paired potentiostat; use the booster when higher current is required without compromising potential regulation. Compatibility Optimised for Corrtest workstations across corrosion, materials and battery research. It is routinely combined with single-channel systems or with one selected channel on multichannel frames. Typical Applications Fuel cell component and MEA testing Battery cell/core and pouch-cell experiments Water electrolysis and electroplating at high current density
| Model / SKU | SCIGEAR00138 |
| Communication | RS485 |
| Current range | 20A/40A/100A fixed range |
| Potential range | Β±10V(CS1020B) / Β±10V(CS1050B) / Β±10V(CS10100B) |
| EIS Frequency range | β€50KHz |